- device ›
- yuwell
- YT-1
- yuwell YT-1 Duo Sensor Infrared Thermometer User Manual


Device use an applicant scope
- This device is used to measure the body temperature by passively sensing infrared heat radiation collected from the human body's forehead, which can be used for families and medical departments to measure the body temperature.
- Intended use and application scope: This device is used to measure the forehead temperature of the human body, which is applicable to infants, children, and adults.
- Contraindication: None.
Device structure and composition
- Device main structure and composition The thermometer consists of a housing, a sensor, a display, and a circuit board.
- LCD area
- Appendix: Instructions, Quick Operation Guide, 2 Section 7 Alkaline Batteries.
The symbols related to safety requirements in this device and their meanings:
Symbols | Implication |
![]() | Type BF application part |
![]() | Caution! Consult instruction of the product |
![]() | Paper recycling |
![]() | This side up |
![]() | Fragile |
![]() | Non-rainproof |
![]() | Not to be disposed of as ordinary waste |
![]() | Electronic information product pollution control mark environmental protection use period is 10 years. Consumables are not included |
Matters need attention
- The measurement result is only for reference, which is not a substitute for a physician's diagnosis. It s very dangerous to self-judge and treats only based on the measurement result. Please follow the doctor's instructions.
- Please put the battery out of the reach of children, otherwise, it is dangerous.
- When the product is not used for a long time (more than 3 months), remove the battery from the device to prevent battery leakage.
- It is forbidden to immerse the infrared thermometer n any liquid, and It is forbidden to use it for a long time under too high or low-temperature conditions. No collisions drop and mix with sharp objects.
- Do not put the battery close to the fire or into the fire to avoid the battery explosion. Do not use the battery when it leaks or molds; when discarding batteries or this product, it should be following local regulations to avoid contamination.
- This product contains sensitive electronic components, should avoid strong electromagnetic interference.
- Please read this instruction carefully before use to confirm that the battery is installed.
- Do not disassemble, repair or remold this device, which may lead to measurement error or machine malfunction.
- This product is not waterproof and should be used carefully to prevent liquid from entering the product. When the product gets wet due to contact with steam, use it after it becomes dry or gently wipe it with a soft dry cloth or cotton ball, otherwise, it will cause measurement errors.
- If there is a temperature difference compared the environment of the device storage with that of the measuring environment, place the device in the measuring environment for more than 30 minutes, otherwise, there may be an error for the measurement result.
- When the lens of the sensor becomes dirty, please wipe it gently with a soft dry cloth or cotton swab. Do not wipe it with other material, otherwise, it may cause lens surface of senor abrasion or machine malfunction.
- Do not try to measure when the device is wet, which may cause measurement results inaccurate.
- Before measurement, please make sure that there are no sweat, cosmetics, or oil stains on the forehead of the subject.
- Before measuring, please make sure that the subject does not take a bath, exercise, or have a meal within 30 minutes, and the body is measured at a steady state.
- Before use, please keep the sensor and cavities clean.
- During measurement, do not let the subject directly face the air outlet of the sun, air conditioner, or heater, which will change the temperature of the forehead. Please conduct measurement in a stable environment as far as possible.
- Under the condition which meets the requirement of storage, the usage period of the device is 5 years(fragile and consumable parts are not included).
Installation and usage
- Installing the battery The device is supplied with 2 Section 7 alkaline batteries. Push the battery cover downward and load the battery into the battery compartment. At this time, the device will start self-inspection. Pay attention to the positive and negative poles instruction in the battery compartment and cover the battery cover. Refer to the picture at right:
- Setting measure unit In the shutdown state, long-press the starting measuring button “
”for 10 seconds to enter the temperature unit conversion state, and then short press the starting measuring button“
” to select “
”and“
”temperature unit.●Measure temperature of human body 1. Point the infrared thermometer probe at the center of the eyebrow, within 0-5cm of the forehead (do not touch the forehead directly).2. Press the Start measuring button “
”. After about 1 second, the infrared thermometer will have vibration and sound prompts to display the measurement results.Notes: ①When the measurement distance is more than about 5 cm, the word "0-5" will be displayed on the screen, please close to the subject, as the picture shows at right;

- Sound on/offsettingWhen the prompt on/off button slides to "
", the sound is off;When the prompt on/off button slides to "
", the sound is on.
- Power off① Long press Starting measurement button" " for 3~5 seconds to turn off the device;②In the absence of any operation, the device will automatically shut down after about 30 seconds.
Product maintenance and upkeep method
As the product is a reusable device, please pay attention to cleaning and disinfection after use. If the product is dirty, please keep the sensor and probe cavity clean, otherwise, the measurement accuracy will be affected.How to clean sensor and probe cavity: gently wipe the inner cavity or sensor mirror with a clean soft cloth orcottonswab.Disinfection of the product and its head: Gently wipe the surface of the product and the head used for measurement with a cotton swab dipped in a little medical alcohol (70%), it can be used until the alcohol has completely evaporated.
- Precaution for storageThis product should be stored in a dust-free, dry place, please avoid direct sunlight; do not store in places with high temperature, humidity, dust, and corrosive gas.This product is a high-precision device, please do not drop the device! Avoid drastic collisions and jolts and other adverse possibilities for transport.If the probe or the product itself has been damaged, do not continue to use it. Please do not use this product for any purposes other than its intended use. When it is used for children, please observe the general safety precautions.
Common failures and troubleshooting methods
Phenomenon of breakdown | Possible cause | Troubleshooting methods |
The screen display" ![]() | The measurement temperature is lower than 32℃, which is beyond the measurement range | Please re-measure following the product instruction |
The screen display" ![]() | The measurement temperature is higher than 43℃, which is beyond the measurement range | Pleasere-measure following the product instruction |
The screen display" ![]() | The environment temperature is too high or too low | Please measure under the 16℃~35℃ environment temperature |
The screen display" ![]() | The power of cells is a shortage | Change the cell |
No display or abnormal display | The positive and negative poles of the cell are reversed or the device is abnormal | Re-install the cell, or contact the dealer |
Measurement and transport storage environment
- measurement environment: Environment temperature: 16℃~35℃ Relative humidity: ≤85%(RH) Atmospheric pressure: 70kPa~106kPa
- Transportation and storage environment: Environment temperature: -20℃~+55℃ Relative humidity: ≤85%(RH) Atmospheric pressure: 70kPa~106kPa
Product technical parameters
- Power source: DC 3V( 2 Section 7 alkaline batteries)
- Measurement range: 32.0℃ ~43.0℃
- Display resolution: 0.1℃
- Measurement accuracy: ±0.2℃ in the range of 35.0℃~42.0℃ ±0.3℃in the range of 32.0℃~34.9℃ and 42.1℃~ 43.0℃
- Electric shock protection: the device is supplied by internal power
- Applied part: BF Type
- Running mode: continuous running
- Temperature units: ℃/℉
- Degrees of protection against ingress liquid: IP20 (solid foreign matter whose diameter are greater than or equal to 12.5mm can be prevented from entering, no protection against ingress liquid )
- Safety classification: the device that cannot be used in the presence of flammable anesthetic gases mixed with air or oxygen or nitrous oxide
- Product size: 149×38×42(mm)
- Product weight: about 68g (not including cell)
Warranty card
Warranty cardProduct name: Infrared thermometerModel: YT-1
The Use of Electromagnetic Environment Guidance
This product complies with the Electromagnetic Compatibility (EMC) standard for the safe operation of electrical equipment for medical use and YY0505-2012.The standard of YY0505-2012 (item 6.8.2.201) stipulates that users should be provided with detailed information related to the EMC environment for the safe operation of equipment. And the following is the description of technical instructions related to EMC. (For details, please refer to YY0505-2012.)The Electromagnetic Compatibility (EMC) standard represented by YY0505 set a criterion for the safe operation of electrical equipment for medical use. The standard stipulates that the interference of the noise generated by the equipment to other devices should be controlled within a certain range, so is the electromagnetic wave dry disturbance emitted by other devices (mobile phones, etc.).
- Definition of EMC (electromagnetic compatibility) EMC refers to the ability to satisfy the following two requirements.●No unallowable electromagnetic interference noise will be emitted to other nearby electronic devices. (Radiation)●The device can work normally in an electromagnetic environment with the noise and other interference from other electronic devices. (Noise immunity)2. Technical specification on EMC (electromagnetic compatibility) Electrical equipment for medical use requires specific instructions for EMC and should be operated inaccordance with the following EMC information .● This device requires special instructions on electromagnetic compatibility (EMC). Please use the device in accordance with the EMC information described in this manual.● Portable and wireless radio frequency (RF) communication devices may affect the device.●When using this device, do not place it adjacent to or stack it with other devices.
Guidelines and Manufacturer's Declaration- Electromagnetic Radiation | ||
The product should only be operated in the electromagnetic environment specified below.Purchasers and users should ensure that the product is operated in the specified electromagnetic environment. | ||
Radiation test | Compliance | Electromagnetic environment - guidelines |
RF radiation GB4824 | Group 1 | This product uses RF energy only for its internal functions.Therefore, the RF radiation is extremely low, which is less likely to produce interference with surrounding electronic devices. |
RF radiation GB4824 | Type B | This product applies to all facilities, including the following ones, namely, the facilities of public low-voltage power grid which are directly connected to family facilities and buildings to achieve power supply. |
Harmonic radiation GB 17625.1 | NA | |
Voltage Variation/ Scintillation GB 17625.2 | NA |
Guidelines and Manufacturer's Declaration- Electromagnetic Immunity | |||
The product should only be operated in the electromagnetic environment specified below.Purchasers and users should ensure that the product is operated in the specified electromagnetic environment. | |||
Immunity test | YY0505Test level | Comp-license level | Electromagnetic environment guideline |
Electrostatic discharge (ESD) GB/T 17626.2 | Exposure±6kVAir±8kV | Exposure ±6kV Air ±8kV | It is highly recommended to pave the ground with wooden, concrete or tile floorings. When the flooring is coated with synthetic materials, the relative humidity (RH) is recommended to be reduced by 30%. |
EFT / Burst GB/T 17626.4 | Power circuit±2kV Incoming/o utput circuit±1kV | NA | NA |
Surge GB/T 17626.5 | ±1 kVwire to wire±2 kVwire to earth wire | NA | NA |
The voltage dip,short-time outage and voltage variation of power input circuit GB/T 17626.11 | <5% UT (>95% UT 'sdip)0.5cycle 40% UT(60% UT 'sdip)5 cycles 70% UT (30% UT 'sdip)25 cycles<5% UT (>95% UT 'sdip)5 cycles | NA | NA |
Power frequency (50/ 60 Hz)Magnetic field GB/T 17626.8 | 3 A/m | 3 A/m | The level of the power frequency magnetic field in commercial environments or hospitals should be the same as that in general venues. |
Note: UT represents AC grid voltage before applying testing voltage. |
Guidelines and Manufacturer's Declaration- Electromagnetic Immunity | |||
The product should only be operated in the electromagnetic environment specified below.Purchasers and users should ensure that the product is operated in the specified electromagnetic environment. | |||
Immunity test | YY0505Test level | Comp- license level | Electromagnetic environment |
Conduct-tion RF GB/T 17626.6Radiation n RF GB/T 17626.3 | 3 Vrms150 kHz~80MHz 3 V/m80 MHz~2.5GHz | NA3 V/m | The portable and mobile RF communication devices should not be used within the recommended spacing distance calculated by the equation corresponding to the transmitter frequency, which is applicable for all parts of the product.The recommended spacing distance is not applicable.d=1.280 MHz ~ 800 MHz d=2.3800 MHz ~ 2.5 GHzIn which, P is Transmitter manufacturer specified by the transmitter manufacturer, which is expressed in Watt(W), and, d is recommended spacing distance, with its unit being meter(m). The electric field strength of a fixed RF transmitter is determined by a site survey of the electromagnetic field a) and should be lower than the compliance level in each frequency range. Interference may be triggered near equipment marked with thefollowing symbols.![]() |
Note 1: When the frequency ranges from 80 MHz to 800, the separation distance for the higher frequency should be applied.Note 2: These guidelines are not applicable to all circumstances for the propagation of electromagnetic waves can also be affected by the absorption and reflection of buildings, objects, and human bodies.a) The electric field strengths produced by stationary transmitters from the base stations of wireless (mobile/wireless) telephones and land mobile radio, amateur radios, AM/FM broadcasts, and television stations cannot be theoretically estimated correctly. |
The recommended separation distance between portable, mobile RF communication devices and the product | |||
The product should be operated in an electromagnetic environment where the RF interference is under control. To restrain electromagnetic interference, purchasers or users of this product shall ensure that the minimum separation distance between the following recommended portable, mobile RF communication devices (transmitters) and the product is maintained according to the maximum rated output of the devices. | |||
The maximum output rating of the transmitter (W) | The separation distance based on the transmitter frequency (m) | ||
150 kHz~80 MHz d=1.2 | 80 MHz~800 MHz d=1.2 | 800 MHz~ 2.5 GHz d=2.3 | |
0.01 | 0.12 | 0.12 | 0.23 |
0.1 | 0.38 | 0.38 | 0.73 |
1 | 1.2 | 1.2 | 2.3 |
10 | 3.8 | 3.8 | 7.3 |
100 | 12 | 12 | 23 |
For those transmitters whose maximum rated outputs are not included in the above table, the recommended separation distance d expressed in meters (m) can be computed by the equation associated with the transmitter frequencies, where P stands for the maximum rated output expressed in watts (W) as specified by the manufacturer of the transmitter.Note 1: When the frequency ranges from 80 MHz to 800, the separation distance for the higher frequency should be applied.Note 2: These guidelines are not applicable to all circumstances for the propagation of electromagnetic waves can also be affected by the absorption and reflection of buildings, objects, and human bodies. |
Part name | Toxic and hazardous substances and the associated compounds or elements | |||||
Lead and its compo unds≤ 1000 PPM | Mercu ry and its compounds≤ 1000PPM | Cami um and its compounds≤100PPM | Hexa talent chromium and its compounds≤ 1000PPM | Polybr dominant ed biphenyl and its compo unds≤ 1000 PPM | Polybr dominant ed diphenyl ether and its compo unds≤ 1000 PPM | |
Plastic Enclosure | ○ | ○ | ○ | ○ | ○ | ○ |
Internal cables | ○ | ○ | ○ | ○ | ○ | ○ |
Circuit board (with LCD) | × | ○ | ○ | ○ | ○ | ○ |
Battery* | ○ | ○ | ○ | ○ | ○ | ○ |
Packing materials | ○ | ○ | ○ | ○ | ○ | ○ |
The table is produced based on the stipulation of SJ/T11364○:It indicates that the content of toxic and hazardous substances in all homogeneous materials of the component is below the limit specified in GB/T26572 standard.×: It Indicates that the content of the toxic and hazardous substance in one of the homogeneous materials of the component exceeds the limit specified in GB/T 26572 standard. |
Registrant / Production Enterprise / After-sales Service Unit:Jiangsu Yuyue Medical Equipment Co., Ltd.Address / Production Address: Yunyang Industrial Park(South of Zhenxin Road), Danyang City, Jiangsu ProvinceTel: 0511-86900833Zipcode: 212300Revision date: April, 2019420X160mm:128g
Documents / Resources
yuwell YT-1 Duo Sensor Infrared Thermometer [pdf] User Manual YT-1, Duo Sensor Infrared Thermometer |
Documents - yuwell – YT-1
[pdf] User Manual Instructions Flyer Amsino is proud to offer Infrared Forehead Thermometer Product s described may not be licensed or available for sale in all countries Please see the Instructions Use Operator Manual a complete listing of YT-1 Infrared-Thermometer Flyer 04-28-20 imgcdn mckesson CumulusWeb Click and learn Amsino is proud to offer Infrared Forehead Thermometer FAST, ACCURATE COMPACT Measures temperatur ... lbs Quantities/Unit: 40 pcs/case Warranty: One year manufacturer warranty Item Code Description YT-1 Infrared Forehead Thermometer Quantity/Unit 40/Case This device is manufactured consistent w... lang:en score:35 filesize: 196 K page_count: 1 document date: 2020-04-28 | |
[pdf] User Manual Instructions Warranty YT 1USER MANUAL yuwell Infrared Thermometer for Adults and Kids Forehead Non ContactBaby with Instant Accurate Reading Fever Alarmand Gentle Vibration Alert UserManual wiki 10 Temperature sense 1 User Manual YUWELL Jiangsu Yuyue Medical Equipment Supply Co Ltd It is forbidden to immerse the infrared thermometer in any liquid use it a long time under too high or low temperature condition And Technical Instruction Please read user manual carefully follow instructions before For date of manufacture please refer packing 14 Warranty card Product name Model JIANGSU YUYUE MEDICAL EQUIPMENT SUPPLY LTD A10Lq4GnXKL m media amazon images I 1. Device use and applicant scope Intended use and application scope: This device is used to measure ... would be worst case. 11 14. Warranty card Warranty card Product name: Infrared thermometer Model: YT-1 YT-1 Infrared Thermometer User Manual And Technical Instruction Please read the user manual ca... lang:en score:33 filesize: 1.02 M page_count: 2 document date: 2020-08-31 | |
[pdf] User Manual Instructions Flyer Amsino is proud to offer Infrared Forehead Thermometer Product s described may not be licensed or available for sale in all countries Please see the Instructions Use Operator Manual a complete listing of indications contraindications warnings and precautions The symbol ® indicates trademark registered YT 1 Flyer 04 28 20 life assist Content Docs Apr 2020 · Amsino is proud to offer Infrared Forehead Thermometer FAST, ACCURATE COMPACT Measures temperatur ... lbs Quantities/Unit: 40 pcs/case Warranty: One year manufacturer warranty Item Code Description YT-1 Infrared Forehead Thermometer Quantity/Unit 40/Case This device is manufactured consistent w... lang:en score:33 filesize: 195.94 K page_count: 1 document date: 2020-06-24 | |
[pdf] User Manual Instructions 190820英文YT 1红外体温计英文说明书 420x160mm User Manual yuwell Infrared Thermometer Forehead Non Contact Digital for Adults and Kids Instant Accurate Reading Fever Alarm with Storage Case Health Personal Care A1osZHkUPTL m media amazon images I ||| 1. Device use and applicant scope Intended use and application scope: This device is used to measure ... would be worst case. 11 14. Warranty card Warranty card Product name: Infrared thermometer Model: YT-1 YT-1 Infrared Thermometer User Manual And Technical Instruction Please read the user manual ca... lang:en score:25 filesize: 1.26 M page_count: 2 document date: 2020-03-06 | |
[pdf] User Manual Instructions Warranty 181210 YT 1 0 5cm 红外体温计说明书 300x165mm 10 Warranty card Product name Infrared thermometer Model 5cm红外体温计说明书 User Manual Life Assist Emergency Medical Supplies Yuwell Defibrion 01 02 03 04 05 06 07 ARKY Device use and applicant scope ●This device is used to measure the body temperature by passively sensing infrared heat radiation collected from human s forehead which can be for described in this manual Portable wireless radio frequency RF communication devices may affect When using do not place it adjacent or stack with other 11 The Use of Electromagnetic Environment Guidance measurement result only reference Please read user carefully follow instructions before For date manufacture please refer packing Thermometer And Technical Instruction Electrical equipment medical requires specific EMC should operated accordance following information product instruction 9 technical parameters Not disposed as ordinary waste screen display main structure composition consists a housing sensor circuit board 4 Matters need attention 3 symbols related safety requirements their meanings Measure Point probe at center defibrion 2020 life assist Content Docs arkycase 1. Device use and applicant scope This device is used to measure the body temperature by passively s ... 68g not including cell 10. Warranty card Warranty card Product name: Infrared thermometer Model: YT-1 06 11.The Use of Electromagnetic Environment Guidance This product complies with the Electroma... lang:en score:20 filesize: 1.28 M page_count: 3 document date: 2019-08-05 | |
[pdf] K201864 accessdata fda gov cdrh docs 20 ||| December 6, 2020 Jiangsu Yuyue Medical Equipment Supply Co., Ltd. Caixia Yang Quality Assurance Yu ... 20 Expiration Date: 06/30/2020 See PRA Statement below. Device Name YUWELL Infrared Thermometer : YT-1,YT-l A,YT- lB,YT-l C,YT-2,YT-2A,YT-2B,YT-2C Indications for Use Describe The YUWELL Infrared... lang:en score:17 filesize: 1.15 M page_count: 9 document date: 0000-00-00 | |
[pdf] COVID 19 product products Personal protective equipment Content Article number Face Masks type IIR 50 pieces Type face masks are fluid resistant ENG ARKY arkycase 2020 10 ||| COVID-19 products Personal protective equipment Face Masks type IIR - 50 pieces Type IIR face masks ... each and can therefore also be used for surfaces in contact with food. Measuring instruments Yuwell YT-1 Infrared Thermometer The Yuwell YT-1 infrared thermometer can measure the body temperature with... lang:en score:16 filesize: 456.22 K page_count: 1 document date: 2020-10-21 | |
[pdf] 190820英文YT 1红外体温计英文说明书 420x160mm Sarunas YT 1 naudotojo instrukcija LT Bekontaktis termometras kūno temperatūrai auregis lt image data Dokumentai kiti Yuwell ||| Numatytas naudojimas ir taikymo sritis: Sis prietaisas yra naudojamas mogaus kno kaktos temperatrai ... O UOSTO NUSTATYMO RF belaidio rysio rangai bandymo specifikacijos a/n Maximum Bluetooth, 10 11 YT-1 Infraraudonj spinduli Termometras Naudojimo instrukcija ir technin informacija Atidiai perskait... lang:id score:15 filesize: 2.57 M page_count: 3 document date: 2020-04-28 | |
[pdf] Catalog Amsino is proud to offer Infrared Forehead Thermometer medbis nl framework modules Catalog media products 00 51 49 files Amsino is proud to offer Infrared Forehead Thermometer FAST, ACCURATE COMPACT Measures temperatur ... lbs Quantities/Unit: 40 pcs/case Warranty: One year manufacturer warranty Item Code Description YT-1 Infrared Forehead Thermometer Quantity/Unit 40/Case This device is manufactured consistent w... lang:en score:15 filesize: 196.01 K page_count: 1 document date: 2020-06-22 | |
[pdf] Covid Amenity image makewebeasy net makeweb 0 aNSsujWTa Document ||| SALIVA MASK -Saliva Mask Food Grade :1 / 1 / 0800773869 Blue Color 3 50 / / ... 3209 / 0800773869 YJ380 , , , 02345 / 0800773869 Infrared Thermometer YT-1 Yuwell LCD C F 0-5 cm. 37.6 C 30 Alkaline AAA 1.5 V 2 149 x 38 x 42 . 68 ... lang:en score:15 filesize: 8.59 M page_count: 73 document date: 0000-00-00 | |
[pdf] K211629 accessdata fda gov cdrh docs 21 ||| December 8, 2021 Honsun Nantong Co., Ltd Iris Du RA Manager No.8, Tongxing Road, Nantong Economic ... Jiangsu Yuyue Medical Equipment Supply Co.,Ltd. Device name: YUWELL Infrared Thermometer Model:YT-1, YT-lA, YT-lB, YT-lC, YT-2, YT-2A, YT-2B, YT-2C 510 K number:K201864 Product code:FLL Regul... lang:en score:15 filesize: 722.6 K page_count: 10 document date: 0000-00-00 | |
[pdf] novamed pl Created Date 5 13 2020 11 29 PM instrukcja termometr yuwell yt 1 media product files i n ||| ... lang:en score:11 filesize: 2.1 M page_count: 2 document date: 2020-05-13 | |
[pdf] kang yu@CN001 YUWELL CONTACTLESS THERMOMETER Medlive Marketing Merchants of Medical Supplies YT 1 ISO Certificate v 1589972791 cdn shopify s files 0266 8563 ||| ... lang:en score:11 filesize: 646.04 K page_count: 1 document date: 2019-09-02 |
tags: Duo Sensor Infrared Thermometer, YT-1, yuwell,